Washington Electrical Administrator (01)
Practice exams for every portion of the Washington Electrical Administrator (01) exam, on the 2020 NEC, with every answer explained.
Every plan includes
- 380+ practice questionsOn the 2020 NEC, across all 19 content areas
- Unlimited timed exams for each portionNEC and Theory (65 questions), Washington Codes (17 questions) and Major Load Calculations (10 questions), scored separately
- Every answer cites the 2020 NECOr Washington’s rules for the Washington Codes portion, with the section it comes from
What’s included
Every plan includes all of it. Plans differ only in how long you have access and how you are billed.
- Custom study sessionsPick how many questions and which areas to drill, and study untimed.
- Explanations that cite the codeEvery answer says why, with the 2020 NEC section it comes from, and calculations are worked step by step.
- Weak-area analyticsYour results by area show what to study next.
- Real human supportEmail us any time and a person answers.
Choose your plan
Same full access on every plan. Pick how long you want it; cancel anytime.
How the real exam is built
The real exam has 3 portions, scored separately: NEC and Theory (65 questions, 4 h), Washington Codes (17 questions, 1 h) and Major Load Calculations (10 questions, 2 h). Our timed exams follow each portion’s areas and weights.
Three sections, each scored on its own at 70%: a strong NEC score does not carry a weak Washington Codes or load-calculation score, and you retake only the section you fail. We give you a full-length practice exam for each section.
NEC and Theory
65 scored · 240 min- Article 90 — introduction2
- Articles 100–110 — definitions, general requirements3
- Articles 200–225, 280–285 — branch circuits, feeders, surge protection3
- Article 230 — services5
- Article 240 — overcurrent protection6
- Article 250 — grounding and bonding6
- Articles 300–398 — wiring methods and materials10
- Articles 400–427, 455–480 — equipment for general use3
- Articles 430–450 — motors, A/C, generators, transformers4
- Article 490 — equipment over 1000 V1
- Articles 500–516 — hazardous locations3
- Articles 517–590 — special occupancies4
- Articles 600–695 — special equipment3
- Articles 700–702 — emergency and standby systems2
- Articles 705–780 — special conditions1
- Articles 800–830 — communications systems1
- General trade knowledge and theory8
Washington Codes
17 scored · 60 min- RCW 19.28 and WAC 296-46B17
Major Load Calculations
10 scored · 120 min- Dwelling, multifamily and commercial service and feeder calculations (Article 220, motor feeders)10
About the Washington Electrical Administrator (01)
Granted by Washington L&I Electrical Program
Washington L&I 01 General Electrical Administrator exam (PSI): NEC and Theory, 65 questions in 4 hours; Washington Codes (RCW 19.28 / WAC 296-46B), 17 questions in 1 hour; Major Load Calculations, 10 questions in 2 hours — 70% on each section, open book, on the 2020 NEC. No L&I approval is needed to sit it.
Eligibility Requirements
None. Anyone may take the administrator exam, with no experience and no L&I approval (WAC 296-46B-935 and -960). An administrator certificate does not let you do electrical installation work; that needs an electrician certificate.
Don't have the hours yet?
No training route is required. Book the exam directly with PSI, using your Social Security number as the candidate ID.
On the 2020 NEC — not the 2023
Washington installations follow the 2023 NEC (the 2026 NEC from December 31, 2026), but the exams stay on the 2020 edition until L&I moves them to the 2026 NEC in July 2027. Material written for 2023 renumbers these rules, including several load-calculation rules. Every question here cites the 2020 section.
| Topic | 2023 NEC (not on your exam) | 2020 NEC |
|---|---|---|
| Dwelling general lighting load (3 VA per ft² in both)220.14(J) | 220.41 | 220.14(J) |
| Non-dwelling general lighting unit loads220.12 | Table 220.42(A) | Table 220.12 |
| Lighting load demand factors220.42 | Table 220.45 | Table 220.42 |
| Non-dwelling receptacle demand factors220.44 | Table 220.47 | Table 220.44 |
| EV charging load in a load calculationArticle 220 | 7,200 VA or the nameplate (220.57) | No such rule |
| Class 1 remote-control and signaling circuitsArticle 725 | Articles 722 and 724 | Article 725 |
Scheduling & Fees
Where to take it
- Administered by
- PSI
- Phone
- (855) 834-8751
- Scheduling window
- Book with PSI whenever you are ready; no L&I approval is needed. After you pass every section, L&I must receive your score reports and the certificate fee within 90 days of your last passing score, or you must retake the exam.
- Reschedule policy
- Cancel or reschedule through the PSI website or by phone at least 2 days before the exam to keep your fee (for a Monday exam, by Saturday). Voicemail or email does not count. A no-show, late arrival or missing ID forfeits the fee.
- Retake policy
- You retake only the sections you failed. Wait at least 14 days between attempts. Under the rule in force since November 20, 2026 (WAC 296-46B-960), you have two years from your first attempt to pass all three sections; after three failures in that period you wait 60 days between attempts until you pass.
Fees
- L&I original administrator certificate, paid with your passing score reports
- $160
- PSI retest, billed by the hour of the sections you retake (1-hour rate)
- $45
- Assigning you to a contractor as its administrator
- $53
- Certificate renewal every 3 years (online / mail, fax or in person)
- $175.70 / $202.20
Keeping Your Certification Active
Renewal requirements
- Cycle
- Every 3 years, on your birthdate
- Continuing education
- 24 hours — Courses must be L&I-approved: at least 8 hours on currently adopted NEC changes and 4 hours on RCW 19.28 and WAC 296-46B; the other 12 can be any approved course. Renewing more than 90 days late means retaking the exam.
Sources: Washington L&I — Electrical administrator · PSI Washington L&I Electrical Certification Candidate Information Bulletin (10/30/2025) · WAC 296-46B-960 — Administrator and electrician examinations (as amended effective 11/20/2026) · WAC 296-46B-909 — Electrical fees (effective 7/1/2026) · RCW 19.28.061 — Administrators and master electricians · L&I Electrical Currents, September 2026 (exams move to the 2026 NEC in July 2027)
Frequently asked questions
How is the 01 Electrical Administrator exam structured?+
Three sections, each scored on its own: NEC and Theory, 65 questions in 4 hours; Washington Codes (RCW 19.28 and WAC 296-46B), 17 questions in 1 hour; and Major Load Calculations, 10 questions in 2 hours. You need 70% on each. Up to 10 unscored trial questions may be added.
Which code edition is the exam on?+
The 2020 NEC. Washington installations moved to the 2023 NEC on April 1, 2024, but L&I has kept the exams on the 2020 edition; its September 2026 newsletter says they will move straight to the 2026 NEC in July 2027. Study material written for 2023 cites several load-calculation rules under different numbers.
Is it open book?+
Yes. You may bring the 2020 NEC and other original published reference books, a silent non-programmable calculator, and RCW 19.28 and WAC 296-46B printed and bound in a three-ring binder. Highlighting and permanent tabs are allowed; handwritten notes and removable tabs are not. L&I publishes "exam friendly" printable versions of the RCW and WAC.
What if I fail one section?+
You retake only the section you failed, and you must wait 14 days after a failed attempt. Washington changed its exam rule on November 20, 2026 (WAC 296-46B-960): you now have two years, not one, to pass every section, and after three failures within that period you wait 60 days between later attempts, not 90. PSI’s bulletin still describes the old one-year window, so go by the rule.
How often do I renew?+
Every three years, on your birthday. You need 24 hours of continuing education, including at least 8 on NEC code update and 4 on RCW 19.28 and WAC 296-46B.
Do I need to be an electrician to take it?+
No. There are no prerequisites and no L&I approval: you book directly with PSI. After you pass every section, send the score reports and the $160 certificate fee to L&I within 90 days of your last passing score, or you must retest.
Administrator or master electrician: which do I need?+
Every Washington electrical contractor must designate an administrator or a master electrician who answers for its code compliance, permits and labels (RCW 19.28.061). An administrator certificate does not let you do installation work; for that you also need an electrician certificate. A general (01) administrator can be assigned to one general contractor or to any specialty contractor.
What changes in 2027?+
L&I will move the exams to the 2026 NEC in July 2027. Until then every section tests the 2020 NEC and the current RCW 19.28 and WAC 296-46B, which Washington amends on its own schedule (the exam rules changed on November 20, 2026, and more WAC amendments take effect with the 2026 NEC on December 31, 2026), so study from current printouts of the law.
Study guides for this exam

Washington Electrical Administrator Exam Day: PSI, What to Bring, and Pacing Three Sections
What to expect on the Washington 01 electrical administrator exam with PSI: booking without L&I approval, ID, the code book, law binder and calculator you may bring, pacing three sections, scoring and retakes.

What's on the Washington Electrical Administrator Exam? All Three Sections and How to Study
The PSI outline for the Washington 01 electrical administrator exam: 65 NEC and Theory questions by article range, 17 Washington Codes questions, 10 major load calculations, 70% on each section, on the 2020 NEC.

Washington Electrical Administrator (01): Requirements, Fees, and How to Get Certified
Washington's 01 general electrical administrator certificate: no experience or L&I approval needed, the three-section PSI exam, the 90-day deadline to apply after passing, fees, assignment to a contractor and renewal.
Ready to pass your exam?
Practice all three portions on the current code, with every calculation worked out.
Start Studying Today →