The Alaska State Fire Marshal (Division of Fire and Life Safety, Department of Public Safety) issues individual fire system permits for alarm, sprinkler, special hazards and kitchen hood work, and every company doing that work must employ a permit holder in the right class. The permit classes are built directly on NICET: Level II for maintenance/testing and installation classes, Level III for design classes. Portable extinguisher technicians need a separate State Fire Marshal permit, either by state written exam (Tech I) or by the ICC/NAFED extinguisher test (Tech II, hydrotesting).

Licensed at the state levelChecked against official sources on November 13, 2026

What each trade needs in Alaska

Fire alarm

  • Fire System Permit Class IA (maintenance/testing) and Class IB (installation, maintenance, testing)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal), Dept. of Public Safety
    Who needs it
    Individuals supervising fire alarm maintenance and testing (IA) or installation (IB, a supervisory position). Each company needs at least one permit holder covering its scope.
    What it takes
    2 years' cumulative fire alarm experience, plus passing the NICET Level II exam elements in fire alarm systems or the equivalent (13 AAC 50.035(g)(3)). The permit is valid 3 years; renewal takes 15 hours of continuing education.

    NICET: NICET Fire Alarm Systems Level II (or equivalent) required

    Source: 13 AAC 50.035 (Permit required), via Cornell LII

  • Fire System Permit Class IC (design, installation, maintenance, testing) and Class IC-DO (design only)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals who design fire alarm systems or supervise preparation of technical documents
    What it takes
    5 years' cumulative experience, a supervisory position, and passing the NICET Level III exam elements in fire alarm systems or the equivalent (13 AAC 50.035(g)(3)). A registered PE with relevant experience is exempt for design. Class IB-Special (install only) goes to Alaska journeyman electricians, with no NICET requirement.

    NICET: NICET Fire Alarm Systems Level III (or equivalent) required

    Source: 13 AAC 50.035, via Cornell LII

Fire sprinkler

  • Fire System Permit Class IIB (sprinkler/standpipe installation, maintenance, testing)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals in a supervisory position over installation, maintenance and testing of water-based systems
    What it takes
    2 years' experience, a supervisory position, and passing the NICET Level II exam elements in inspection and testing of water-based systems or the equivalent (13 AAC 50.035(g)(3)(G)).

    NICET: NICET Inspection & Testing of Water-Based Systems Level II (or equivalent) required

    Source: 13 AAC 50.035, via Cornell LII

  • Fire System Permit Class IIC (design, installation, maintenance, testing) and Class IIC-DO (design only)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals who design sprinkler and standpipe systems. In Anchorage, fire system plans must also come from an IC, IIC or IIIC permit holder or a fire protection PE.
    What it takes
    5 years' experience, a supervisory position, and NICET Level III in automatic sprinkler systems (IIC) or automatic sprinkler systems layout (IIC-DO), or the equivalent (13 AAC 50.035(g)(3)).

    NICET: NICET Water-Based Systems Layout Level III (or equivalent) required

    Source: 13 AAC 50.035, via Cornell LII

Inspection, testing and maintenance

  • Fire System Permit Class IIA (sprinkler/standpipe maintenance and testing)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals doing maintenance and testing of water sprinkler and standpipe systems
    What it takes
    2 years' experience, plus passing the NICET Level II exam elements in automatic sprinkler systems or the equivalent (13 AAC 50.035(g)(3)(F)).

    NICET: NICET Level II in automatic sprinkler systems (layout), or equivalent, required

    Source: 13 AAC 50.035, via Cornell LII

Special hazards suppression

  • Fire System Permit Class IIIA / IIIB (maintenance, testing, installation) and IIIC / IIIC-DO (design)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals working on or designing special hazard systems
    What it takes
    IIIA/IIIB: 2 years' experience and NICET Level II in special hazard systems, or the equivalent. IIIC/IIIC-DO: 5 years' experience and NICET Level III in special hazard systems (layout), or the equivalent (13 AAC 50.035(g)(3)).

    NICET: NICET Special Hazards Systems Level II (A/B classes) or Level III (C classes) required, or equivalent

    Source: 13 AAC 50.035, via Cornell LII

Extinguishers and kitchen suppression

  • Fire System Permit Class IV (pre-engineered kitchen hood systems)

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Individuals installing, maintaining and testing pre-engineered dry/wet chemical systems for restaurant and commercial hoods
    What it takes
    2 years' experience; passing the NICET Level II exam or the equivalent, or the ICC/NAFED Pre-engineered Kitchen Fire Extinguishing System Technician (FK) test; at least one manufacturer's training certificate; and the system manuals (13 AAC 50.035(g)(3)(N)).

    NICET: NICET II or equivalent accepted

    ICC: ICC/NAFED Pre-engineered Kitchen Fire Extinguishing System Technician (FK) accepted

    Source: 13 AAC 50.035, via Cornell LII

  • Fire Extinguisher Technician I and II permits

    Issued by
    Alaska Division of Fire and Life Safety (State Fire Marshal)
    Who needs it
    Anyone who inspects, recharges, maintains or hydrostatically tests portable extinguishers (owner monthly inspections excepted)
    What it takes
    Tech I (inspect, recharge, maintain): pass a written exam given by the State Fire Marshal. Tech II (adds hydrostatic testing): pass the ICC/NAFED Certified Portable Fire Extinguisher Technician test. Permits are valid 3 years (13 AAC 50.030(d)).

    ICC: ICC/NAFED Certified Portable Fire Extinguisher Technician required for Tech II

    State exam: State Fire Marshal written exam for Fire Extinguisher Technician I

    Source: 13 AAC 50.030 (Fire protection systems, installed and portable), via Cornell LII

Practice for these credentials

These national exams are named in the requirements above. Each has a free sample test.

NICET Fire Alarm Systems

Most-pursued fire-alarm credential — design, layout & installation.

Named in: Fire System Permit Class IA (maintenance/testing) and Class IB (installation, maintenance, testing); Fire System Permit Class IC (design, installation, maintenance, testing) and Class IC-DO (design only)

NICET I&T of Water-Based Systems

Test and service sprinklers, standpipes & fire pumps in-field.

Named in: Fire System Permit Class IIB (sprinkler/standpipe installation, maintenance, testing)

NICET Water-Based Systems Layout

Sprinkler & standpipe layout — design, hangers, hydraulics.

Named in: Fire System Permit Class IIC (design, installation, maintenance, testing) and Class IIC-DO (design only); Fire System Permit Class IIA (sprinkler/standpipe maintenance and testing)

NICET Special Hazards Systems

CO₂, clean agent, water mist, foam & deluge suppression systems.

Named in: Fire System Permit Class IIIA / IIIB (maintenance, testing, installation) and IIIC / IIIC-DO (design)

ICC Kitchen Suppression Technician

Install & service wet chemical systems over commercial cooking.

Named in: Fire System Permit Class IV (pre-engineered kitchen hood systems)

ICC Portable Extinguisher Technician

Service, inspect & recharge portable fire extinguishers.

Named in: Fire Extinguisher Technician I and II permits