Chicago Supervising Electrician (Low Voltage)
Practice exams for the Chicago Supervising Electrician (Low Voltage) exam, on the 2018 Chicago Electrical Code, weighted like the real outline.
Every plan includes
- 570+ practice questionsOn the 2018 Chicago Electrical Code, across all 11 content areas
- Unlimited 100-question timed exams3 h, the same length as the real exam
- Every answer cites the codeThe 2018 Chicago Electrical Code, with the section each answer comes from
What’s included
Every plan includes all of it. Plans differ only in how long you have access and how you are billed.
- Custom study sessionsPick how many questions and which areas to drill, and study untimed.
- Explanations that cite the codeEvery answer says why, with the code section it comes from.
- Weak-area analyticsYour results by area show what to study next.
- Real human supportEmail us any time and a person answers.
Choose your plan
Same full access on every plan. Pick how long you want it; cancel anytime.
How the real exam is built
The real exam: 100 questions across 11 areas in 3 h. Our timed exams use the same areas and weights.
You need 70. CTS publishes a range of questions for each area; we use the middle of each range, with wiring and protection, equipment for general use and special occupancies at the low end of theirs so the exam totals 100, and our full-length practice exam draws from each area in those proportions.
Supervising Electrician (Low Voltage) exam
100 scored · 180 min- Electrical Principles and Practices18
- OSHA Regulations and Workplace Safety7
- Titles 2, 4 and 13 (Code Supplement)6
- General Provisions (Articles 90-110)7
- Wiring and Protection (200s)10
- Wiring Methods and Materials (300s)15
- Equipment for General Use (400s)6
- Special Occupancies (500s)6
- Special Equipment (600s)7
- Special Conditions (700s)7
- Communication Systems (800s)11
About the Chicago Supervising Electrician (Low Voltage)
Granted by City of Chicago Department of Buildings
City of Chicago Supervising Low Voltage Electrician exam, given by Continental Testing Services for the Department of Buildings: 100 open-book questions in 3 hours, 70 to pass, on the 2018 Chicago Electrical Code (the 2017 NEC with Title 14E amendments), Municipal Code Titles 2, 4 and 13, electrical principles and OSHA 1926.
Eligibility Requirements
At least 21 years old, with at least two years of experience installing, altering, repairing and maintaining electrical wiring and equipment under the direct supervision of a supervising electrician or equivalent person, verified by letters from your supervisors (4-292-020).
On the 2017 NEC, as Chicago amends it
The 2018 Chicago Electrical Code is the 2017 NEC with the changes in Title 14E of the Municipal Code, in force since March 1, 2018. Chicago rewrites some rules, adds articles of its own and drops others entirely. Where Chicago changes a rule, our questions follow the Chicago rule, not the national text. Some of the differences:
| Topic | 2017 NEC (national) | Chicago (2018 Chicago Electrical Code) |
|---|---|---|
| Class 2 and 3 cable in plenums725.135(B), (C); 760.135; 770.113; 800.113 | Types CL2P and CL3P cable permitted in other spaces used for environmental air | Installed by the plenum wiring methods of 300.22(C); the same rule applies to fire alarm, optical fiber and communications cable |
| Fire alarm power supply760.184 | A branch circuit that supplies no other loads | Primary power for a required fire alarm system comes from the Article 700 emergency system, on circuits grouped and identified “FIRE ALARM CIRCUIT” |
| Fire alarm control equipment760.185 | No location rule | In a dedicated one-hour fire-rated room, never below grade |
| Fire alarm conductor size760.183 | 18 AWG and 16 AWG permitted in raceway, an approved enclosure or a listed cable | 16 AWG minimum (18 AWG only in a multiconductor cable), with no more than 5% voltage drop on secondary power |
| Connection to a municipal fire alarm box760.210(A) | No such rule | Metal conduit, at least 2 in. and buried 24 in. outside, with five 14 AWG or larger conductors of different colors |
| Branch circuits under IT-room raised floors645.5(E) | The plenum methods of 300.22(C) plus a list that includes nonmetallic raceways and MC, AC and TC cable | Metal raceways only: RMC, IMC, EMT, metal wireway, surface metal raceway, FMC or LFMC |
| Fire-resistive cable systemsArticle 728 | NEC Article 728 | Not adopted in Chicago |
| Emergency systemsArticle 700 | NEC Article 700 | Not adopted; Chicago writes its own Article 700 (System I, II and III emergency lighting) |
Scheduling & Fees
Where to take it
- Administered by
- Continental Testing Services (CTS)
- Scheduling window
- Continental Testing Services processes applications and gives the paper exam in Chicago about three times a year. Upcoming dates: March 10, 2027 (register by February 5), July 21, 2027 (by June 16) and November 17, 2027 (by October 13).
- Reschedule policy
- There are no make-up exams and no refunds. If you miss your date, register for the next one.
- Retake policy
- You need 70. After a failed exam you must wait six months before applying to retake it (4-292-020(d)), and each attempt costs the $150 exam fee.
Fees
- Exam fee, each attempt (2026)
- $150
- Initial supervising electrician license (2026)
- $150
- Annual renewal (2026)
- $150
Keeping Your Certification Active
Renewal requirements
- Cycle
- Every year, through the Department of Buildings portal; a license expired three years or more cannot be renewed
- Continuing education
- No continuing education requirement appears in Chapter 4-292 or on the Department of Buildings page. A supervising electrician who has not acted as one in the city, or pulled a permit, for three continuous years must pass the exam again (4-292-070).
Reciprocity
Chicago does not license by reciprocity. Because Illinois has no state license, many suburbs set their own rules, and several accept the Chicago exam; Aurora’s contractor testing sheet (2013) lists Chicago among the municipal tests it accepts. Check with each town.
Sources: Chicago Department of Buildings: Supervising Electrician License · Continental Testing Services: Chicago Supervising Electrician · Chicago Department of Buildings: Electrical Contractor License (general and low voltage scope) · CTS Chicago Supervising Electricians Licensure Examination Study Guide (2018) · CTS: Selected Provisions of Titles 2, 4 and 13 (Code Supplement, amendments through 12/13/2017) · Municipal Code of Chicago, Title 14E Electrical Code (American Legal Publishing) · Substitute Ordinance SO2017-5529: the 2017 Chicago Electrical Code (passed 9/6/2017)
Frequently asked questions
How is the Chicago Supervising Electrician (Low Voltage) exam structured?+
One paper exam of 100 four-option questions in 3 hours, and you need 70. The first 25 questions cover electrical principles and practices: theory, blueprint reading, transformers and delta/wye loads, power factor, voltage drop and 6 to 8 OSHA 1926 safety questions. The other 75 cover the Chicago Electrical Code by NEC chapter, with wiring methods (14 to 16), communication systems (10 to 12) and wiring and protection (10 to 12) the largest, plus 5 to 7 questions on Municipal Code Titles 2, 4 and 13.
What work does a low voltage license cover?+
A supervising electrician’s license type follows the exam passed, and an electrical contractor’s license type follows its supervising electrician’s. A low voltage contractor and its employees may only do electrical work on Class 1, 2 and 3 remote-control, signaling and power-limited circuits and communications circuits. For any other electrical work you need the General exam.
Is the Low Voltage exam only about low-voltage articles?+
No. CTS uses the same outline as the General exam, with fewer questions per area, so expect questions from every NEC chapter: grounding, wiring methods, equipment, special occupancies and emergency systems as well as Articles 725, 760, 770 and 800 to 840. Chicago’s own rules for fire alarm systems and for cabling in plenums and risers are worth knowing well.
What do I need before I can sit the exam?+
The same as for the General exam: you must be at least 21 and have at least two years of experience installing, altering, repairing and maintaining electrical wiring and equipment under the direct supervision of a supervising electrician or equivalent person, verified by letters from your supervisors. You apply through Continental Testing Services, which processes applications for the Department of Buildings.
Which code book can I bring?+
Only a clean, printed copy of the 2018 Chicago Electrical Code (NFPA’s book: the 2017 NEC with Chicago’s Title 14E amendments). Tabs may mark sections, but notes and highlighting are not allowed, and no other books or materials are permitted. CTS also hands every candidate a clean copy of “Selected Provisions of Titles 2, 4 and 13,” which you can download from the CTS site to study from.
How is the exam given?+
Continental Testing Services gives it for the Department of Buildings, on paper, in person in Chicago, about three times a year. Bring two sharpened No. 2 pencils and a silent, non-programmable solar or battery calculator; there is no power at the test site. There are no make-up exams and no refunds; if you miss a date, register for the next one.
What score do I need, and can I retake it?+
You need 70. If you fail, the Municipal Code (4-292-020(d)) makes you wait six months before you apply to retake the exam, and each attempt costs the $150 exam fee.
Which city law is on the exam?+
About 8 to 10 questions on the General exam (5 to 7 on the Low Voltage exam) come from Titles 2, 4 and 13 of the Municipal Code, as printed in the CTS handout: the Department of Buildings, electrical contractor and supervising electrician licensing, and old Title 13 on electrical permits, wires on the public way and penalties. That handout reflects the code as of December 2017, before the administrative provisions moved to Title 14A in 2019, so study it rather than the current Title 14A.
Are the questions up to date?+
Most questions are keyed to the 2018 Chicago Electrical Code by section number, and CTS says more than 75% of the answers are in that book. CTS’s question bank also keeps some older items with legacy wording or article numbers, so read each question carefully and find the current rule in the book.
How often do I renew?+
Every year, for $150. No continuing education requirement is listed in Chapter 4-292 or on the Department of Buildings page. A license expired three years or more cannot be renewed, and a supervising electrician who has not acted as one in the city or pulled a permit for three continuous years must retake the exam (4-292-070).
Do other towns accept the Chicago license?+
Illinois has no state electrician license, so each town sets its own rules. Many suburbs accept the Chicago supervising electrician exam; Aurora’s contractor testing sheet, for example, lists Chicago among the municipal tests it accepts. That sheet dates from 2013, so confirm with the town before you apply.
Ready to pass your exam?
Practice the full exam on the current code, with every calculation worked out.
Start Studying Today →