Virginia Fire Alarm Contractor (FAS): Qualified Individual Requirements
How a Virginia contractor gets the Fire Alarm Systems (FAS) specialty: the Qualified Individual, the 1/3/5-year experience rule, the PSI technical exam, fees and what the ELE classification already covers.
Contents
Virginia Fire Alarm Contractor (FAS): Qualified Individual Requirements
Virginia doesn't license fire alarm technicians one by one. It licenses the contracting firm. A firm that installs, repairs or improves fire alarm systems carries the Fire Alarm Systems Contracting (FAS) specialty on its contractor license, issued by the Department of Professional and Occupational Regulation (DPOR), Board for Contractors. Every specialty on a license needs a Qualified Individual, and for FAS that person has to pass a technical exam given by PSI.
What the FAS specialty covers
PSI's exam outline defines FAS as "the installation, repair, or improvement of fire alarm systems that operate at 50 volts or less." It adds that "the ELE classification also provides for this function." A firm already licensed in the Electrical (ELE) classification can do fire alarm work without adding FAS. The FAS specialty is for alarm companies that aren't electrical contractors.
The Qualified Individual
DPOR requires each licensed firm to name a Qualified Individual (QI) for each classification and specialty printed on its license. The QI must be a full-time employee or a member of the firm's responsible management. Experience depends on the license class the firm holds:
| Firm's license class | QI experience in the specialty |
|---|---|
| Class C | at least 1 year |
| Class B | at least 3 years |
| Class A | at least 5 years |
Since December 1, 2012, a new license, a specialty added to an existing license, or a change of QI also needs a qualifying credential. For FAS, that credential is the PSI technical exam, "VA Fire Alarm Systems Contracting." No NICET or other certificate stands in for it.
How the process works
- Apply to DPOR. The QI is approved through the firm's license application, an additional-specialty application, or a QI change form. DPOR makes the candidate eligible to test.
- Schedule with PSI. Register at PSI's Virginia contractor page and pick a test center or a remote-proctored session. Eligibility lasts one year.
- Pass the exam. 50 questions, 2 hours, open book, 70% to pass. You can retake it as often as you need during the eligibility year.
- Finish the license. Use the same identification number (SSN or DMV number) when you schedule the exam and when you apply for the license.
Fees
PSI charges $85 per attempt. The fee is non-refundable and good for one year. DPOR's license application fees are separate and depend on the class of license.
Renewal
Virginia contractor licenses renew every two years. The FAS Qualified Individual has no continuing education requirement. If your QI leaves, the firm has to name a new one, and the new QI must meet the experience rule and pass the exam.
The other Virginia fire specialties
- Fire Suppression (FSP): halon and other gaseous agent, dry chemical and CO2 systems. Its QI takes a separate PSI exam.
- Fire Sprinkler (SPR): no exam. The QI needs NICET Level III or higher, or a Virginia PE license with sprinkler experience.
- Certified Automatic Fire Sprinkler Inspector: an individual certification based on NICET Inspection and Testing of Water-Based Systems Level II or higher.
Next steps
See what is on the FAS exam and what to expect on exam day. Our Virginia FAS practice exam follows PSI's outline, and the free sample test lets you try 10 questions first.
Sources: DPOR Board for Contractors exam information (A501-27EXINFO, 09/01/2025), PSI's Virginia Contractor Specialty candidate information bulletin (5/20/2024) and the PSI Fire Alarm Systems Contracting content outline, read November 2026. Confirm requirements and fees with DPOR before you apply.
Ready to pass Virginia Fire Alarm Systems Contractor (FAS)?
Start your prep with unlimited practice tests and codebook-referenced answers.
Start Studying →