Utah State Fire Marshal Exam Topics: What Each Certification Exam Covers
What the Utah State Fire Marshal fire alarm, extinguisher, kitchen suppression, KES and sprinkler inspection exams cover: the NFPA standards and editions, the R710 rules, and how to study for an open-book exam.
Contents
Utah State Fire Marshal Exam Topics: What Each Certification Exam Covers
Every Utah State Fire Marshal (SFM) certification exam is built the same way: an open-book written test on the NFPA standard for your work, the Utah rule for your trade, and the statute, with two hours and 70% to pass. The SFM publishes the books, not question counts or topic weights, so the job is knowing which book each exam leans on and where in it to look fast.
The books, exam by exam
| Exam | Main standard | Utah rule | Other |
|---|---|---|---|
| Basic Fire Alarm Technician | NFPA 72 (2019) | — | — |
| Fire Alarm Technician | NFPA 72 (2019) | R710-11, R710-4 | — |
| Master Fire Alarm Technician | NFPA 72 (2019) | — | IFC Chapter 9 (the SFM provides a copy) |
| Portable fire extinguisher | NFPA 10 (2018) | R710-1 | Statute |
| Automatic fire suppression (kitchen) | NFPA 17A, NFPA 96 | R710-7 | Statute |
| Kitchen exhaust system (KES) | NFPA 96, NFPA 17A | R710-7 | — |
| Sprinkler Technician I | NFPA 25, 13, 14 | R710-5 | — |
| Sprinkler Technician II | NFPA 25, 20, 22, 13 | — | — |
| Sprinkler Technician III | NFPA 25, 15 | — | — |
A note on editions. The SFM's fire alarm and extinguisher pages name NFPA 72 (2019) and NFPA 10 (2018), and Utah's rule R710-4 still defines NFPA 72 as the 2019 edition. The SFM's "Current Code Books" page, adopted July 1, 2026, lists newer editions: NFPA 72 (2022), NFPA 10 (2022), NFPA 13, 13R and 13D (2022), NFPA 25 (2023), NFPA 14 (2024), NFPA 20 (2022), NFPA 22 (2023), NFPA 96 (2024) and NFPA 17A (2021). Ask the SFM which edition your exam uses before you buy a book, and bring that one.
Fire alarm
Basic is about the fundamentals and testing: NFPA 72 definitions, circuit classes and pathway survivability, documentation, and above all Chapter 14, inspection, testing and maintenance (test methods and frequencies, what goes on the record of completion). Expect initiating devices (Chapter 17) and notification appliances (Chapter 18) too.
Fire Alarm Technician adds testing and maintenance for buildings up to four stories and the Utah rules:
- R710-11: who needs a certificate, the three levels, the task book, the 3-year re-examination, and the service tag (size, any color but red, what it must show, the red tag for a failing system and the copy to the AHJ). Fire alarm systems must be inspected annually, and a new system is exempt for a year after acceptance.
- R710-4: the fire alarm features Utah requires in state-regulated buildings, such as complete-coverage detection in unsprinklered state-owned buildings, schools and I and R-4 occupancies, manual boxes in a school's boiler room, kitchen and main office, where the main panel goes, and Class A circuits.
Master moves to high-rise buildings, voice evacuation and smoke control: NFPA 72 Chapter 21 (emergency control functions such as elevator recall and HVAC shutdown) and Chapter 24 (emergency communications systems), plus IFC Chapter 9, where Section 907 sets when an alarm system is required and Section 909 covers smoke control.
Portable extinguishers
NFPA 10 splits into two halves the exam uses heavily:
- Selection and installation: classes of fire, ratings, hazard classification, travel distance and coverage, mounting heights.
- Inspection, maintenance, recharging and hydrostatic testing: monthly inspection versus annual maintenance, 6-year maintenance and 12-year hydrostatic test intervals by extinguisher type, recharging agents, and which extinguishers must be removed from service.
R710-1 brings the Utah side: concern license types, the shop's minimum equipment and records, the certificate of registration and its 5-year re-examination, the service tag layout and wording ("DO NOT REMOVE, BY ORDER OF THE STATE FIRE MARSHAL"), and who may remove a tag or label.
Kitchen suppression and KES
The suppression exam rests on NFPA 17A (wet chemical systems: listing, detection, manual pull stations, fuel and power shut-off, six-month inspection and maintenance, fusible link replacement) and NFPA 96 (hoods, grease removal devices, ducts, clearances and the fire-extinguishing equipment section). R710-7 adds the Utah rules: license classes H1 and H2, the UL 300 requirement, the HE certificate number, six-month maintenance, fusible links dated by year and replaced semiannually, no mixing of parts between manufacturers, and red non-compliance tags reported to the local fire chief.
The KES exam weighs NFPA 96 more heavily, especially the inspection, cleaning and maintenance chapter: inspection frequencies by cooking volume and fuel, cleaning to bare metal, access panels, and the report after service. It then adds NFPA 17A material the cleaner must not disturb, and R710-7.
Sprinkler inspection and testing
All three levels sit mainly on NFPA 25, so learn its layout: the inspection, testing and maintenance tables at the start of each chapter, then the detail sections.
- Technician I: NFPA 25 sprinkler and standpipe chapters plus the valve chapter (control valves, alarm devices, main drain tests, gauges, antifreeze testing), NFPA 13 system types and components, NFPA 14 standpipe basics, and R710-5 (levels, task books, the 3-year re-examination, service tags at the riser, the label for passed 3- and 5-year inspections, and Utah's two amendments to NFPA 25 Table 5.1).
- Technician II: dry pipe, deluge and preaction valves (trip tests, quick-opening devices, air pressure), fire pumps (weekly or monthly churn tests and the annual flow test, NFPA 20 basics) and water tanks (NFPA 25 tank chapter and NFPA 22).
- Technician III: NFPA 25 water spray and foam-water chapters (nozzles, strainers, operational tests, foam concentrate sampling) and NFPA 15 water spray systems.
How to study for an open-book exam
Open book does not mean easy. Two hours goes quickly if you have to search the whole of NFPA 25 for every question.
- Tab your books by chapter and mark the inspection and testing tables you will use most.
- Learn each standard's layout, so you know a frequency question means a table and a definition question means Chapter 3.
- Read the Utah rule once, fully. It is short, it is free, and the questions about tags, re-examination and certificates come straight from it.
- Practise against the clock. Our Utah State Fire Marshal practice exams give you nine 50-question, 2-hour exams, one per certificate, each answer citing the section or rule it comes from. Try the free 10-question sample test first.
Read who needs which certificate and what happens on exam day next.
Sources: Utah State Fire Marshal licensing and certification pages and Current Code Books page, and Utah Admin. Code R710-1, R710-4, R710-5, R710-7 and R710-11, read November 2026.